Spiral Freezers
•
Cryogenic spiral freezers
• Mechanical spiral freezers
• Cryogenic spiral freezers convertible
into mechanical spiral freezers
Freezing
Tunnels
• Continuous in-line I.Q.F. freezing tunnel
• “Cryofood” cryogenic freezing
tunnel with trays
• “Cryofood” mechanical
freezing tunnel with trays
• Quick-freeze linear tunnels
Freezing
Chambers
• Mechanical freezing chambers
• Cryogenic freezing chambers
------------------
•
Leavening
• Pasteurization
• Baking
• Protection
• New Production Lines
|
Class 100 Vertical Laminar Air Flow
Hoods
|
COGIL’s vertical laminar air flow hoods effectively
protect the work areas by generating a controlled flow
of sterile air and achieving better than class 100 air
quality.
This method facilitates any processes that require total
protection against bacteria, moulds and other contaminants
that are normally found in the atmosphere.
Because of their features, these hoods can be used successfully
in numberless applications, especially in the food and
pharmaceutical industries, where protecting products from
contamination is a vital point.
Each hood has the following characteristics:
100% stainless steel AISI 304 construction with satin
finish.
Each hood comes complete with a built-in suction compartment
above the absolute filters. Here is where the fan and
the air pre-filters will be installed.
The hood is built in such a way as to allow the installation
of the absolute filters to be carried out from the side
panels side.
The electric panel in each hood is placed in the suction
compartment.
Air velocity
Air velocity is 0.45 m/s and the flow is uniform over
the entire work area. Air velocity can be regulated to
within ± 10% of the standard value by means of
an electronic controller that will change the revs of
the electric fans. Filtration
The air that is made to circulate by means of the electric
fans will flow through Viledon pre-filters, with efficiency
80% D.O.P., and then through the absolute filters with
efficiency equal to 99.999 D.O.P. – 0.3 micron test.
|
Tests before delivery
The
following tests are carried out on each hood before delivery:
1.Visual inspection of components.
2.Run test.
3.Alarm and electric protection test.
4.European safety regulations and EC certification requirements
compliance test
5.Perimetral filter leak check with particle counter.
6.Air purity check according to
Federal Standard 209E.
7.Air velocity uniformity check.
8.Sound level check.
Documentation supplied with each hood
1.Installation, operating and maintenance manual.
2.Wiring diagrams.
3.Machine drawings with dimensions and heights.
4.Spare parts list.
5.Test and inspection reports.
6. Copies of absolute filter efficiency certificates.
7.Copies of testing instruments calibration certificates.
8.CE declaration of conformity
(in accordance with point A, Annexe II of Directive 89/392/EEC).
|
Protection hood
for powder weighting
Vial machine protected
by a vertical laminar air
flow hood
Down Cross hood
Hood protecting against biological risks
|
|